| LC50 | ≤15 arcsecConfiguration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 1,247 N·mConfiguration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 2,500 rpmConfiguration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 611 N·mConfiguration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 30 arcsecConfiguration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Backlash≤15 arcsec Manufacturer specification Configuration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC50",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 611,
"maximumAllowableTorque": 1247,
"permissibleAverageInputSpeed": 2500
} Maximum allowable torque1,247 N·m Manufacturer specification Configuration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC50",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 611,
"maximumAllowableTorque": 1247,
"permissibleAverageInputSpeed": 2500
} Permissible average input speed2,500 rpm Manufacturer specification Configuration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC50",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 611,
"maximumAllowableTorque": 1247,
"permissibleAverageInputSpeed": 2500
} Rated torque611 N·m Manufacturer specification Configuration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC50",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 611,
"maximumAllowableTorque": 1247,
"permissibleAverageInputSpeed": 2500
} Transmission error30 arcsec Manufacturer specification Configuration: LC50; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC50",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 611,
"maximumAllowableTorque": 1247,
"permissibleAverageInputSpeed": 2500
} |
|---|
| LC45 | ≤15 arcsecConfiguration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 982 N·mConfiguration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 3,000 rpmConfiguration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 459 N·mConfiguration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 30 arcsecConfiguration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Backlash≤15 arcsec Manufacturer specification Configuration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC45",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 459,
"maximumAllowableTorque": 982,
"permissibleAverageInputSpeed": 3000.0
} Maximum allowable torque982 N·m Manufacturer specification Configuration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC45",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 459,
"maximumAllowableTorque": 982,
"permissibleAverageInputSpeed": 3000.0
} Permissible average input speed3,000 rpm Manufacturer specification Configuration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC45",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 459,
"maximumAllowableTorque": 982,
"permissibleAverageInputSpeed": 3000.0
} Rated torque459 N·m Manufacturer specification Configuration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC45",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 459,
"maximumAllowableTorque": 982,
"permissibleAverageInputSpeed": 3000.0
} Transmission error30 arcsec Manufacturer specification Configuration: LC45; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC45",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 459,
"maximumAllowableTorque": 982,
"permissibleAverageInputSpeed": 3000.0
} |
|---|
| LC40 | ≤15 arcsecConfiguration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 738 N·mConfiguration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 3,000 rpmConfiguration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 345 N·mConfiguration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 30 arcsecConfiguration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Backlash≤15 arcsec Manufacturer specification Configuration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC40",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 345,
"maximumAllowableTorque": 738,
"permissibleAverageInputSpeed": 3000.0
} Maximum allowable torque738 N·m Manufacturer specification Configuration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC40",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 345,
"maximumAllowableTorque": 738,
"permissibleAverageInputSpeed": 3000.0
} Permissible average input speed3,000 rpm Manufacturer specification Configuration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC40",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 345,
"maximumAllowableTorque": 738,
"permissibleAverageInputSpeed": 3000.0
} Rated torque345 N·m Manufacturer specification Configuration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC40",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 345,
"maximumAllowableTorque": 738,
"permissibleAverageInputSpeed": 3000.0
} Transmission error30 arcsec Manufacturer specification Configuration: LC40; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC40",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 345,
"maximumAllowableTorque": 738,
"permissibleAverageInputSpeed": 3000.0
} |
|---|
| LC32 | ≤15 arcsecConfiguration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 433 N·mConfiguration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 3,500 rpmConfiguration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 178 N·mConfiguration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 30 arcsecConfiguration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Backlash≤15 arcsec Manufacturer specification Configuration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC32",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 178,
"maximumAllowableTorque": 433,
"permissibleAverageInputSpeed": 3500
} Maximum allowable torque433 N·m Manufacturer specification Configuration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC32",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 178,
"maximumAllowableTorque": 433,
"permissibleAverageInputSpeed": 3500
} Permissible average input speed3,500 rpm Manufacturer specification Configuration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC32",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 178,
"maximumAllowableTorque": 433,
"permissibleAverageInputSpeed": 3500
} Rated torque178 N·m Manufacturer specification Configuration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC32",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 178,
"maximumAllowableTorque": 433,
"permissibleAverageInputSpeed": 3500
} Transmission error30 arcsec Manufacturer specification Configuration: LC32; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC32",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 178,
"maximumAllowableTorque": 433,
"permissibleAverageInputSpeed": 3500
} |
|---|
| LC25 | ≤15 arcsecConfiguration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 204 N·mConfiguration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 3,500 rpmConfiguration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 87 N·mConfiguration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 30 arcsecConfiguration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Backlash≤15 arcsec Manufacturer specification Configuration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC25",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 87,
"maximumAllowableTorque": 204,
"permissibleAverageInputSpeed": 3500
} Maximum allowable torque204 N·m Manufacturer specification Configuration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC25",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 87,
"maximumAllowableTorque": 204,
"permissibleAverageInputSpeed": 3500
} Permissible average input speed3,500 rpm Manufacturer specification Configuration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC25",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 87,
"maximumAllowableTorque": 204,
"permissibleAverageInputSpeed": 3500
} Rated torque87 N·m Manufacturer specification Configuration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC25",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 87,
"maximumAllowableTorque": 204,
"permissibleAverageInputSpeed": 3500
} Transmission error30 arcsec Manufacturer specification Configuration: LC25; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC25",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 87,
"maximumAllowableTorque": 204,
"permissibleAverageInputSpeed": 3500
} |
|---|
| LC20 | ≤15 arcsecConfiguration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 107 N·mConfiguration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 3,500 rpmConfiguration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 52 N·mConfiguration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 30 arcsecConfiguration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Backlash≤15 arcsec Manufacturer specification Configuration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC20",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 52,
"maximumAllowableTorque": 107,
"permissibleAverageInputSpeed": 3500
} Maximum allowable torque107 N·m Manufacturer specification Configuration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC20",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 52,
"maximumAllowableTorque": 107,
"permissibleAverageInputSpeed": 3500
} Permissible average input speed3,500 rpm Manufacturer specification Configuration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC20",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 52,
"maximumAllowableTorque": 107,
"permissibleAverageInputSpeed": 3500
} Rated torque52 N·m Manufacturer specification Configuration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC20",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 52,
"maximumAllowableTorque": 107,
"permissibleAverageInputSpeed": 3500
} Transmission error30 arcsec Manufacturer specification Configuration: LC20; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC20",
"transmissionError": 30,
"backlash": "≤15",
"ratedTorque": 52,
"maximumAllowableTorque": 107,
"permissibleAverageInputSpeed": 3500
} |
|---|
| LC17 | ≤15 arcsecConfiguration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 70 N·mConfiguration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 3,500 rpmConfiguration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 31 N·mConfiguration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 40 arcsecConfiguration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Backlash≤15 arcsec Manufacturer specification Configuration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC17",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 31,
"maximumAllowableTorque": 70,
"permissibleAverageInputSpeed": 3500
} Maximum allowable torque70 N·m Manufacturer specification Configuration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC17",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 31,
"maximumAllowableTorque": 70,
"permissibleAverageInputSpeed": 3500
} Permissible average input speed3,500 rpm Manufacturer specification Configuration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC17",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 31,
"maximumAllowableTorque": 70,
"permissibleAverageInputSpeed": 3500
} Rated torque31 N·m Manufacturer specification Configuration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC17",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 31,
"maximumAllowableTorque": 70,
"permissibleAverageInputSpeed": 3500
} Transmission error40 arcsec Manufacturer specification Configuration: LC17; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC17",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 31,
"maximumAllowableTorque": 70,
"permissibleAverageInputSpeed": 3500
} |
|---|
| LC14 | ≤15 arcsecConfiguration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 36 N·mConfiguration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 3,500 rpmConfiguration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 10 N·mConfiguration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | 40 arcsecConfiguration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Backlash≤15 arcsec Manufacturer specification Configuration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC14",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 10,
"maximumAllowableTorque": 36,
"permissibleAverageInputSpeed": 3500
} Maximum allowable torque36 N·m Manufacturer specification Configuration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC14",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 10,
"maximumAllowableTorque": 36,
"permissibleAverageInputSpeed": 3500
} Permissible average input speed3,500 rpm Manufacturer specification Configuration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC14",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 10,
"maximumAllowableTorque": 36,
"permissibleAverageInputSpeed": 3500
} Rated torque10 N·m Manufacturer specification Configuration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC14",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 10,
"maximumAllowableTorque": 36,
"permissibleAverageInputSpeed": 3500
} Transmission error40 arcsec Manufacturer specification Configuration: LC14; Exact official model row joined by public application logic and labelled with official table units. Peak/maximum duration and test conditions are not specified. Linksoon official public product definitions (deterministic model/parameter extraction) {
"model": "LC14",
"transmissionError": 40,
"backlash": "≤15",
"ratedTorque": 10,
"maximumAllowableTorque": 36,
"permissibleAverageInputSpeed": 3500
} |
|---|