Product family

LCSG-II standard cup reducers

4 variants · Varies by frame size, reduction ratio

Leader Harmonious Drive Systems

About this product family

Manufacturer-defined LCSG-II standard cup reducers family, with size and configuration details recorded on each individual model.

Compare variants

Values retain their source conditions and claim stage. A missing value means it has not been published in this catalogue.

Variant / modelAllowable average input speedAllowable average torqueAllowable maximum momentary torqueAllowable start/stop peak torqueBacklash upper limitDetails & evidence
LCSG-25-XXX-C-II

3,500 r/minConfiguration: LCSG-25-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. The manual calls this allowable average input speed; it is not the rated-torque test speed of2000r/min.

133 N·mConfiguration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

133 N·mConfiguration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

133 N·mConfiguration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

68.5 N·mConfiguration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

107.5 N·mConfiguration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

351 N·mConfiguration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

376 N·mConfiguration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

388 N·mConfiguration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

230 N·mConfiguration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

315 N·mConfiguration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

194 N·mConfiguration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

207 N·mConfiguration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

217 N·mConfiguration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

121 N·mConfiguration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

169 N·mConfiguration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

20 arcsecConfiguration: LCSG-25-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Upper bound, expressed as ≤ in the manufacturer table.

Full specifications
Source-backed claims

Specifications & evidence

Source-backed claims. Configuration, workload and evidence type matter when comparing products.

Allowable average input speed

3,500 r/min

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. The manual calls this allowable average input speed; it is not the rated-torque test speed of2000r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Allowable average torque

133 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 100 | 84 | 194 | 133 | 351 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable average torque

133 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 120 | 84 | 207 | 133 | 376 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable average torque

133 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 160 | 84 | 217 | 133 | 388 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable average torque

68.5 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Allowable average torque

107.5 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 80 | 78 | 169 | 107.5 | 315 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable maximum momentary torque

351 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 100 | 84 | 194 | 133 | 351 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable maximum momentary torque

376 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 120 | 84 | 207 | 133 | 376 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable maximum momentary torque

388 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 160 | 84 | 217 | 133 | 388 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable maximum momentary torque

230 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Allowable maximum momentary torque

315 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 80 | 78 | 169 | 107.5 | 315 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable start/stop peak torque

194 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 100 | 84 | 194 | 133 | 351 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable start/stop peak torque

207 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 120 | 84 | 207 | 133 | 376 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable start/stop peak torque

217 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 160 | 84 | 217 | 133 | 388 | 5500 | 3500 | ≤20 | 1.48 | 15000

Allowable start/stop peak torque

121 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Allowable start/stop peak torque

169 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 80 | 78 | 169 | 107.5 | 315 | 5500 | 3500 | ≤20 | 1.48 | 15000

Backlash upper limit

20 arcsec

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Upper bound, expressed as ≤ in the manufacturer table.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 100 | 84 | 194 | 133 | 351 | 5500 | 3500 | ≤20 | 1.48 | 15000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 120 | 84 | 207 | 133 | 376 | 5500 | 3500 | ≤20 | 1.48 | 15000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 160 | 84 | 217 | 133 | 388 | 5500 | 3500 | ≤20 | 1.48 | 15000

Design life

10,000 h

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 80 | 78 | 169 | 107.5 | 315 | 5500 | 3500 | ≤20 | 1.48 | 15000

Drawing axial span callout

50

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; manual drawing page 8; Exact drawing callout. The drawing does not print a dimensional unit; retained as text without inferring millimetres. Confirm units before mechanical design.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
50

Input connection

Input connection through an Oldham coupling

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; Manufacturer current series description; form identity is also explicitly named in the hosted manual drawings. No newer performance ratings transferred.

LCS(G) (High-torque) Standard Cup-shaped Strain Wave Gear-Leaderdrive
LCSG-II: The input shaft is connected to the wave generator's inner hole through an Oldham coupling.

Mass

1.48 kg

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Maximum input speed

5,500 r/min

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Outer flange diameter callout

⌀107 h7

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; manual drawing page 8; Exact drawing callout, including h7 fit notation. The drawing does not print a dimensional unit; no unit inferred. Confirm units and the full drawing before mechanical design.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
⌀107 h7

Rated torque

84 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 100 | 84 | 194 | 133 | 351 | 5500 | 3500 | ≤20 | 1.48 | 15000

Rated torque

84 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 120 | 84 | 207 | 133 | 376 | 5500 | 3500 | ≤20 | 1.48 | 15000

Rated torque

84 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 160 | 84 | 217 | 133 | 388 | 5500 | 3500 | ≤20 | 1.48 | 15000

Rated torque

48 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Rated torque

78 N·m

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 80 | 78 | 169 | 107.5 | 315 | 5500 | 3500 | ≤20 | 1.48 | 15000

Reduction ratio

100 :1

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 100 | 84 | 194 | 133 | 351 | 5500 | 3500 | ≤20 | 1.48 | 15000

Reduction ratio

120 :1

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 120 | 84 | 207 | 133 | 376 | 5500 | 3500 | ≤20 | 1.48 | 15000

Reduction ratio

160 :1

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 160 | 84 | 217 | 133 | 388 | 5500 | 3500 | ≤20 | 1.48 | 15000

Reduction ratio

50 :1

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 50 | 48 | 121 | 68.5 | 230 | 5500 | 3500 | ≤20 | 1.48 | 10000

Reduction ratio

80 :1

Manufacturer specification

Configuration: LCSG-25-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
25 | 80 | 78 | 169 | 107.5 | 315 | 5500 | 3500 | ≤20 | 1.48 | 15000
LCSG-17-XXX-C-II

3,500 r/minConfiguration: LCSG-17-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. The manual calls this allowable average input speed; it is not the rated-torque test speed of2000r/min.

48.5 N·mConfiguration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

48.5 N·mConfiguration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

32.5 N·mConfiguration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

33.5 N·mConfiguration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

134 N·mConfiguration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

107 N·mConfiguration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

86 N·mConfiguration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

108 N·mConfiguration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

66 N·mConfiguration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

66 N·mConfiguration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

42 N·mConfiguration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

53 N·mConfiguration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

20 arcsecConfiguration: LCSG-17-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Upper bound, expressed as ≤ in the manufacturer table.

Full specifications
Source-backed claims

Specifications & evidence

Source-backed claims. Configuration, workload and evidence type matter when comparing products.

Allowable average input speed

3,500 r/min

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. The manual calls this allowable average input speed; it is not the rated-torque test speed of2000r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Allowable average torque

48.5 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 100 | 30 | 66 | 48.5 | 134 | 7000 | 3500 | ≤20 | 0.69 | 15000

Allowable average torque

48.5 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 120 | 30 | 66 | 48.5 | 107 | 7000 | 3500 | ≤20 | 0.69 | 15000

Allowable average torque

32.5 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Allowable average torque

33.5 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 80 | 27.5 | 53 | 33.5 | 108 | 7000 | 3500 | ≤20 | 0.69 | 15000

Allowable maximum momentary torque

134 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 100 | 30 | 66 | 48.5 | 134 | 7000 | 3500 | ≤20 | 0.69 | 15000

Allowable maximum momentary torque

107 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 120 | 30 | 66 | 48.5 | 107 | 7000 | 3500 | ≤20 | 0.69 | 15000

Allowable maximum momentary torque

86 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Allowable maximum momentary torque

108 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 80 | 27.5 | 53 | 33.5 | 108 | 7000 | 3500 | ≤20 | 0.69 | 15000

Allowable start/stop peak torque

66 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 100 | 30 | 66 | 48.5 | 134 | 7000 | 3500 | ≤20 | 0.69 | 15000

Allowable start/stop peak torque

66 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 120 | 30 | 66 | 48.5 | 107 | 7000 | 3500 | ≤20 | 0.69 | 15000

Allowable start/stop peak torque

42 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Allowable start/stop peak torque

53 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 80 | 27.5 | 53 | 33.5 | 108 | 7000 | 3500 | ≤20 | 0.69 | 15000

Backlash upper limit

20 arcsec

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Upper bound, expressed as ≤ in the manufacturer table.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 100 | 30 | 66 | 48.5 | 134 | 7000 | 3500 | ≤20 | 0.69 | 15000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 120 | 30 | 66 | 48.5 | 107 | 7000 | 3500 | ≤20 | 0.69 | 15000

Design life

10,000 h

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 80 | 27.5 | 53 | 33.5 | 108 | 7000 | 3500 | ≤20 | 0.69 | 15000

Drawing axial span callout

39

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; manual drawing page 7; Exact drawing callout. The drawing does not print a dimensional unit; retained as text without inferring millimetres. Confirm units before mechanical design.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
39

Input connection

Input connection through an Oldham coupling

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; Manufacturer current series description; form identity is also explicitly named in the hosted manual drawings. No newer performance ratings transferred.

LCS(G) (High-torque) Standard Cup-shaped Strain Wave Gear-Leaderdrive
LCSG-II: The input shaft is connected to the wave generator's inner hole through an Oldham coupling.

Mass

0.69 kg

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Maximum input speed

7,000 r/min

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Outer flange diameter callout

⌀79 h7

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; manual drawing page 7; Exact drawing callout, including h7 fit notation. The drawing does not print a dimensional unit; no unit inferred. Confirm units and the full drawing before mechanical design.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
⌀79 h7

Rated torque

30 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 100 | 30 | 66 | 48.5 | 134 | 7000 | 3500 | ≤20 | 0.69 | 15000

Rated torque

30 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 120 | 30 | 66 | 48.5 | 107 | 7000 | 3500 | ≤20 | 0.69 | 15000

Rated torque

19.8 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Rated torque

27.5 N·m

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 80 | 27.5 | 53 | 33.5 | 108 | 7000 | 3500 | ≤20 | 0.69 | 15000

Reduction ratio

100 :1

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 100 | 30 | 66 | 48.5 | 134 | 7000 | 3500 | ≤20 | 0.69 | 15000

Reduction ratio

120 :1

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 120 | 30 | 66 | 48.5 | 107 | 7000 | 3500 | ≤20 | 0.69 | 15000

Reduction ratio

50 :1

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 50 | 19.8 | 42 | 32.5 | 86 | 7000 | 3500 | ≤20 | 0.69 | 10000

Reduction ratio

80 :1

Manufacturer specification

Configuration: LCSG-17-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
17 | 80 | 27.5 | 53 | 33.5 | 108 | 7000 | 3500 | ≤20 | 0.69 | 15000
LCSG-40-XXX-C-II

3,000 r/minConfiguration: LCSG-40-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. The manual calls this allowable average input speed; it is not the rated-torque test speed of2000r/min.

460 N·mConfiguration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

557 N·mConfiguration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

557 N·mConfiguration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

242 N·mConfiguration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

351 N·mConfiguration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

1,334 N·mConfiguration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

1,458 N·mConfiguration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

1,458 N·mConfiguration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

847 N·mConfiguration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

1,210 N·mConfiguration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

702 N·mConfiguration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

762 N·mConfiguration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

800 N·mConfiguration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

497 N·mConfiguration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

641 N·mConfiguration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

20 arcsecConfiguration: LCSG-40-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Upper bound, expressed as ≤ in the manufacturer table.

Full specifications
Source-backed claims

Specifications & evidence

Source-backed claims. Configuration, workload and evidence type matter when comparing products.

Allowable average input speed

3,000 r/min

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. The manual calls this allowable average input speed; it is not the rated-torque test speed of2000r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Allowable average torque

460 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 100 | 328 | 702 | 460 | 1334 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable average torque

557 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 120 | 363 | 762 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable average torque

557 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 160 | 363 | 800 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable average torque

242 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Allowable average torque

351 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 80 | 255 | 641 | 351 | 1210 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable maximum momentary torque

1,334 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 100 | 328 | 702 | 460 | 1334 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable maximum momentary torque

1,458 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 120 | 363 | 762 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable maximum momentary torque

1,458 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 160 | 363 | 800 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable maximum momentary torque

847 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Allowable maximum momentary torque

1,210 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 80 | 255 | 641 | 351 | 1210 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable start/stop peak torque

702 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 100 | 328 | 702 | 460 | 1334 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable start/stop peak torque

762 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 120 | 363 | 762 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable start/stop peak torque

800 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 160 | 363 | 800 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Allowable start/stop peak torque

497 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Allowable start/stop peak torque

641 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 80 | 255 | 641 | 351 | 1210 | 4000 | 3000 | ≤20 | 5.0 | 15000

Backlash upper limit

20 arcsec

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Upper bound, expressed as ≤ in the manufacturer table.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 100 | 328 | 702 | 460 | 1334 | 4000 | 3000 | ≤20 | 5.0 | 15000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 120 | 363 | 762 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 160 | 363 | 800 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Design life

10,000 h

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 80 | 255 | 641 | 351 | 1210 | 4000 | 3000 | ≤20 | 5.0 | 15000

Drawing axial span callout

71.5

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; manual drawing page 9; Exact drawing callout. The drawing does not print a dimensional unit; retained as text without inferring millimetres. Confirm units before mechanical design.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
71.5

Input connection

Input connection through an Oldham coupling

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; Manufacturer current series description; form identity is also explicitly named in the hosted manual drawings. No newer performance ratings transferred.

LCS(G) (High-torque) Standard Cup-shaped Strain Wave Gear-Leaderdrive
LCSG-II: The input shaft is connected to the wave generator's inner hole through an Oldham coupling.

Mass

5 kg

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Maximum input speed

4,000 r/min

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Outer flange diameter callout

⌀160 h7

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; manual drawing page 9; Exact drawing callout, including h7 fit notation. The drawing does not print a dimensional unit; no unit inferred. Confirm units and the full drawing before mechanical design.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
⌀160 h7

Rated torque

328 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 100 | 328 | 702 | 460 | 1334 | 4000 | 3000 | ≤20 | 5.0 | 15000

Rated torque

363 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 120 | 363 | 762 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Rated torque

363 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 160 | 363 | 800 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Rated torque

169 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Rated torque

255 N·m

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 80 | 255 | 641 | 351 | 1210 | 4000 | 3000 | ≤20 | 5.0 | 15000

Reduction ratio

100 :1

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 100 | 328 | 702 | 460 | 1334 | 4000 | 3000 | ≤20 | 5.0 | 15000

Reduction ratio

120 :1

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 120:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 120 | 363 | 762 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Reduction ratio

160 :1

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 160:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 160 | 363 | 800 | 557 | 1458 | 4000 | 3000 | ≤20 | 5.0 | 15000

Reduction ratio

50 :1

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 50 | 169 | 497 | 242 | 847 | 4000 | 3000 | ≤20 | 5.0 | 10000

Reduction ratio

80 :1

Manufacturer specification

Configuration: LCSG-40-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
40 | 80 | 255 | 641 | 351 | 1210 | 4000 | 3000 | ≤20 | 5.0 | 15000
LCSG-14-XXX-C-II

3,500 r/minConfiguration: LCSG-14-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. The manual calls this allowable average input speed; it is not the rated-torque test speed of2000r/min.

13.5 N·mConfiguration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

8.6 N·mConfiguration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

13.5 N·mConfiguration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

66 N·mConfiguration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

43 N·mConfiguration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

57 N·mConfiguration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

34 N·mConfiguration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

23 N·mConfiguration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

29 N·mConfiguration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

20 arcsecConfiguration: LCSG-14-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Upper bound, expressed as ≤ in the manufacturer table.

Full specifications
Source-backed claims

Specifications & evidence

Source-backed claims. Configuration, workload and evidence type matter when comparing products.

Allowable average input speed

3,500 r/min

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. The manual calls this allowable average input speed; it is not the rated-torque test speed of2000r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Allowable average torque

13.5 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 100 | 9.6 | 34 | 13.5 | 66 | 8000 | 3500 | ≤20 | 0.52 | 15000

Allowable average torque

8.6 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Allowable average torque

13.5 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Allowable average torque limit.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 80 | 9.6 | 29 | 13.5 | 57 | 8000 | 3500 | ≤20 | 0.52 | 15000

Allowable maximum momentary torque

66 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 100 | 9.6 | 34 | 13.5 | 66 | 8000 | 3500 | ≤20 | 0.52 | 15000

Allowable maximum momentary torque

43 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Allowable maximum momentary torque

57 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Momentary maximum, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 80 | 9.6 | 29 | 13.5 | 57 | 8000 | 3500 | ≤20 | 0.52 | 15000

Allowable start/stop peak torque

34 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 100 | 9.6 | 34 | 13.5 | 66 | 8000 | 3500 | ≤20 | 0.52 | 15000

Allowable start/stop peak torque

23 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Allowable start/stop peak torque

29 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Start/stop peak limit, not continuous torque.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 80 | 9.6 | 29 | 13.5 | 57 | 8000 | 3500 | ≤20 | 0.52 | 15000

Backlash upper limit

20 arcsec

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Upper bound, expressed as ≤ in the manufacturer table.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 100 | 9.6 | 34 | 13.5 | 66 | 8000 | 3500 | ≤20 | 0.52 | 15000

Design life

10,000 h

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Design life

15,000 h

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Manufacturer design-life claim; not a warranty or verified service life.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 80 | 9.6 | 29 | 13.5 | 57 | 8000 | 3500 | ≤20 | 0.52 | 15000

Drawing axial span callout

36

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; manual drawing page 7; Exact drawing callout. The drawing does not print a dimensional unit; retained as text without inferring millimetres. Confirm units before mechanical design.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
36

Input connection

Input connection through an Oldham coupling

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; Manufacturer current series description; form identity is also explicitly named in the hosted manual drawings. No newer performance ratings transferred.

LCS(G) (High-torque) Standard Cup-shaped Strain Wave Gear-Leaderdrive
LCSG-II: The input shaft is connected to the wave generator's inner hole through an Oldham coupling.

Mass

0.52 kg

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Maximum input speed

8,000 r/min

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Outer flange diameter callout

⌀73 h7

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; manual drawing page 7; Exact drawing callout, including h7 fit notation. The drawing does not print a dimensional unit; no unit inferred. Confirm units and the full drawing before mechanical design.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
⌀73 h7

Rated torque

9.6 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 100 | 9.6 | 34 | 13.5 | 66 | 8000 | 3500 | ≤20 | 0.52 | 15000

Rated torque

6.6 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Rated torque

9.6 N·m

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. Rated at an input speed of 2000 r/min.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 80 | 9.6 | 29 | 13.5 | 57 | 8000 | 3500 | ≤20 | 0.52 | 15000

Reduction ratio

100 :1

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 100:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 100 | 9.6 | 34 | 13.5 | 66 | 8000 | 3500 | ≤20 | 0.52 | 15000

Reduction ratio

50 :1

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 50:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 50 | 6.6 | 23 | 8.6 | 43 | 8000 | 3500 | ≤20 | 0.52 | 10000

Reduction ratio

80 :1

Manufacturer specification

Configuration: LCSG-14-XXX-C-II; ratio 80:1; manual page 6; Manufacturer hosted LCSG manual, form-specific parameter table. Current official series webpage publishes differing values without identifying the applicable generation; these source editions are not interchangeable. XXX is the manufacturer-printed ratio placeholder, not a fully configured order code.

LCSG Product Introduction Manual — form-specific parameter tables and drawings
14 | 80 | 9.6 | 29 | 13.5 | 57 | 8000 | 3500 | ≤20 | 0.52 | 15000

Related products

Contact Us

If you have any questions or would like to get in touch, please feel free to reach out to us at the email below.

info@robotuo.com

YOUR CHOICES

Privacy settings

Choose each optional purpose. All are off until you agree. Change or withdraw consent at any time; browsing still works if you reject all.

Privacy preference

Remembers the choice you make here.

Always active

Save comparisons and followed companies and products between visits. Turning this off deletes saved selections; you can still use them during this visit.

Allow Google Analytics through Firebase to measure general page visits and usage with cookies and device information. Advertising remains off.

Allow OneSignal to process browser and subscription information for Robotuo news and updates. Browser permission is a separate step.

Your shortlist

0 companies selectedUp to 10

Your shortlist is empty. Browse companies and add the ones you’d like to connect with.