| G1300-296400 | 90–264 VACConfiguration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Lead-acidConfiguration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤8.0 ±20% AConfiguration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLead-acid Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Lead-Acid battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤8.0 ±20% A Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤8.0A ±20% ≤5.4A ±20% ≤4.0A ±20% ≤3.2A ±20% ≤2.6A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current40.0±10% A Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 27.0A±10% 20.0A±10% 16.0A±10% 13.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-296400; lead-acid family feature statement, PDF page1; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page1 feature text says4 stages for lead-acid, while page6 explicitly labels3 stages. Both claims are preserved; no arbitrary correction. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging-curve stages3 Manufacturer specification Configuration: G1300-296400; lead-acid charging-curve heading, PDF page6; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page6 curve heading says3 stages for lead-acid while page1 feature text says4. Float-voltage row is retained separately; no source claim is silently selected. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)3 stage charging curve(Lead-Acid battery charger) Charging-voltage adjustment range20.0-29.6 V Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-29.6V 30.0-44.4V 40.0-59.2V 50.0-74.0V 60.0-88.8V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)93 % Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Float charging voltage27.6±1% V Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Float charge(Low voltage) 27.6V±1% 41.4V±1% 55.2V±1% 69.0V±1% 82.8V±1% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... High charging voltage29.6±1% V Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage (High voltage) 29.6V±1% 44.4V±1% 59.2V±1% 74.0V±1% 88.8V±1% Input current (typical)14 A Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC(Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>15.5V*N Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >15.5V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC Emission Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity160 - 400 Ah Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity 160 - 400Ah 100 - 300Ah 80 - 200Ah 60 - 160Ah 50 - 130Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 6 W Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 6W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-296400; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 1 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-288400 | 90–264 VACConfiguration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | LiFePO4Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | Not published | User-defined or factory-default CAN protocolConfiguration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤4 ±20% AConfiguration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLiFePO4 Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LiFePO4 battery chargers Battery leakage current (typical, source notation)≤1Ma Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source notation gap: the manufacturer prints ≤1Ma with ambiguous capitalization. The value is preserved literally; it is not silently normalized to mA or interpreted as megaamperes. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1Ma Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤4 ±20% A Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤3.3A ±20% ≤2.7A ±20% ≤2.0A ±20% ≤1.66A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current40.0±10% A Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 33.0A±10% 27A±10% 20.0A±10% 16.6A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-288400; G1300 family feature statement, PDF page1; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage28.8±1% V Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 28.8V±1% 36.0V±1% 43.2V±1% 57.6V±1% 72.0V±1% Charging-voltage adjustment range20.0-28.8 V Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-28.8V 25.0-36.0V 30.0-43.2V 40.0-57.6V 50.0-72.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)93 % Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>3.7V*N Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >3.7V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Pre-charge current8±10% A Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 6.6A±10% 5.4A±10% 4.0A±10% 3.32A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity40 - 400 Ah Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 33 - 330Ah 27 - 270Ah 20 - 200Ah 16 - 160Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-288400; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 1 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-592200 | 90–264 VACConfiguration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Lead-acidConfiguration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤4.0 ±20% AConfiguration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLead-acid Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Lead-Acid battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤4.0 ±20% A Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤8.0A ±20% ≤5.4A ±20% ≤4.0A ±20% ≤3.2A ±20% ≤2.6A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current20.0±10% A Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 27.0A±10% 20.0A±10% 16.0A±10% 13.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-592200; lead-acid family feature statement, PDF page1; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page1 feature text says4 stages for lead-acid, while page6 explicitly labels3 stages. Both claims are preserved; no arbitrary correction. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging-curve stages3 Manufacturer specification Configuration: G1300-592200; lead-acid charging-curve heading, PDF page6; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page6 curve heading says3 stages for lead-acid while page1 feature text says4. Float-voltage row is retained separately; no source claim is silently selected. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)3 stage charging curve(Lead-Acid battery charger) Charging-voltage adjustment range40.0-59.2 V Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-29.6V 30.0-44.4V 40.0-59.2V 50.0-74.0V 60.0-88.8V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)94 % Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Float charging voltage55.2±1% V Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Float charge(Low voltage) 27.6V±1% 41.4V±1% 55.2V±1% 69.0V±1% 82.8V±1% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... High charging voltage59.2±1% V Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage (High voltage) 29.6V±1% 44.4V±1% 59.2V±1% 74.0V±1% 88.8V±1% Input current (typical)14 A Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC(Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>15.5V*N Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >15.5V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC Emission Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity80 - 200 Ah Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity 160 - 400Ah 100 - 300Ah 80 - 200Ah 60 - 160Ah 50 - 130Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 6 W Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 6W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-592200; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 3 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-444270 | 90–264 VACConfiguration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Lead-acidConfiguration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤5.4 ±20% AConfiguration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLead-acid Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Lead-Acid battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤5.4 ±20% A Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤8.0A ±20% ≤5.4A ±20% ≤4.0A ±20% ≤3.2A ±20% ≤2.6A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current27.0±10% A Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 27.0A±10% 20.0A±10% 16.0A±10% 13.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-444270; lead-acid family feature statement, PDF page1; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page1 feature text says4 stages for lead-acid, while page6 explicitly labels3 stages. Both claims are preserved; no arbitrary correction. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging-curve stages3 Manufacturer specification Configuration: G1300-444270; lead-acid charging-curve heading, PDF page6; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page6 curve heading says3 stages for lead-acid while page1 feature text says4. Float-voltage row is retained separately; no source claim is silently selected. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)3 stage charging curve(Lead-Acid battery charger) Charging-voltage adjustment range30.0-44.4 V Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-29.6V 30.0-44.4V 40.0-59.2V 50.0-74.0V 60.0-88.8V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)94 % Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Float charging voltage41.4±1% V Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Float charge(Low voltage) 27.6V±1% 41.4V±1% 55.2V±1% 69.0V±1% 82.8V±1% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... High charging voltage44.4±1% V Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage (High voltage) 29.6V±1% 44.4V±1% 59.2V±1% 74.0V±1% 88.8V±1% Input current (typical)14 A Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC(Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>15.5V*N Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >15.5V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC Emission Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity100 - 300 Ah Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity 160 - 400Ah 100 - 300Ah 80 - 200Ah 60 - 160Ah 50 - 130Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 6 W Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 6W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-444270; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 2 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-888130 | 90–264 VACConfiguration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Lead-acidConfiguration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤2.6 ±20% AConfiguration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLead-acid Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Lead-Acid battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤2.6 ±20% A Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤8.0A ±20% ≤5.4A ±20% ≤4.0A ±20% ≤3.2A ±20% ≤2.6A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current13.0±10% A Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 27.0A±10% 20.0A±10% 16.0A±10% 13.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-888130; lead-acid family feature statement, PDF page1; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page1 feature text says4 stages for lead-acid, while page6 explicitly labels3 stages. Both claims are preserved; no arbitrary correction. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging-curve stages3 Manufacturer specification Configuration: G1300-888130; lead-acid charging-curve heading, PDF page6; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page6 curve heading says3 stages for lead-acid while page1 feature text says4. Float-voltage row is retained separately; no source claim is silently selected. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)3 stage charging curve(Lead-Acid battery charger) Charging-voltage adjustment range60.0-88.8 V Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-29.6V 30.0-44.4V 40.0-59.2V 50.0-74.0V 60.0-88.8V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)94 % Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Float charging voltage82.8±1% V Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Float charge(Low voltage) 27.6V±1% 41.4V±1% 55.2V±1% 69.0V±1% 82.8V±1% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... High charging voltage88.8±1% V Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage (High voltage) 29.6V±1% 44.4V±1% 59.2V±1% 74.0V±1% 88.8V±1% Input current (typical)14 A Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC(Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>15.5V*N Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >15.5V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC Emission Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity50 - 130 Ah Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity 160 - 400Ah 100 - 300Ah 80 - 200Ah 60 - 160Ah 50 - 130Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 6 W Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 6W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-740160 | 90–264 VACConfiguration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Lead-acidConfiguration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤3.2 ±20% AConfiguration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLead-acid Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Lead-Acid battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤3.2 ±20% A Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤8.0A ±20% ≤5.4A ±20% ≤4.0A ±20% ≤3.2A ±20% ≤2.6A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current16.0±10% A Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 27.0A±10% 20.0A±10% 16.0A±10% 13.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-740160; lead-acid family feature statement, PDF page1; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page1 feature text says4 stages for lead-acid, while page6 explicitly labels3 stages. Both claims are preserved; no arbitrary correction. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging-curve stages3 Manufacturer specification Configuration: G1300-740160; lead-acid charging-curve heading, PDF page6; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page6 curve heading says3 stages for lead-acid while page1 feature text says4. Float-voltage row is retained separately; no source claim is silently selected. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)3 stage charging curve(Lead-Acid battery charger) Charging-voltage adjustment range50.0-74.0 V Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-29.6V 30.0-44.4V 40.0-59.2V 50.0-74.0V 60.0-88.8V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)94 % Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Float charging voltage69.0±1% V Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Float charge(Low voltage) 27.6V±1% 41.4V±1% 55.2V±1% 69.0V±1% 82.8V±1% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... High charging voltage74.0±1% V Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage (High voltage) 29.6V±1% 44.4V±1% 59.2V±1% 74.0V±1% 88.8V±1% Input current (typical)14 A Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC(Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green
digital power for details.
2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves
5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system
complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component
power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>15.5V*N Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >15.5V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC Emission Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity60 - 160 Ah Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity 160 - 400Ah 100 - 300Ah 80 - 200Ah 60 - 160Ah 50 - 130Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 6 W Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 6W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-740160; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 4 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-588200 | 90–264 VACConfiguration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Li-ionConfiguration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤2.0 ±20% AConfiguration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLi-ion Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Li-ion battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤2.0 ±20% A Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤2.8A ±20% ≤2.2A ±20% ≤2.0A ±20% ≤1.4A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part. Charging current20±10% A Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 28.0A±10% 22.0A±10% 20A±10% 14.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-588200; G1300 family feature statement, PDF page1; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage58.8±1% V Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 29.4V±1% 42.0V±1% 54.6V±1% 58.8V±1% 84.0V±1% Charging-voltage adjustment range35-58.8 V Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 17.5-29.4V 25.0-42.0V 32.5-54.6V 35-58.8V 50.0-84.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency94 % Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (full load @ AC230V.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY & EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)110% max. output Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer writes 110% max. output without explicitly stating voltage versus another output quantity; preserved literally. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage 110% max. output Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @Full load Pre-charge current4.0±10% A Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 5.6A±10% 4.4A±10% 4.0A±10% 2.8A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity20 - 200 Ah Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 28 - 280Ah 22 - 220Ah 20 - 200Ah 14 - 140Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-588200; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 4 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-720166 | 90–264 VACConfiguration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | LiFePO4Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | Not published | User-defined or factory-default CAN protocolConfiguration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤1.66 ±20% AConfiguration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLiFePO4 Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LiFePO4 battery chargers Battery leakage current (typical, source notation)≤1Ma Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source notation gap: the manufacturer prints ≤1Ma with ambiguous capitalization. The value is preserved literally; it is not silently normalized to mA or interpreted as megaamperes. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1Ma Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤1.66 ±20% A Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤3.3A ±20% ≤2.7A ±20% ≤2.0A ±20% ≤1.66A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current16.6±10% A Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 33.0A±10% 27A±10% 20.0A±10% 16.6A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-720166; G1300 family feature statement, PDF page1; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage72.0±1% V Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 28.8V±1% 36.0V±1% 43.2V±1% 57.6V±1% 72.0V±1% Charging-voltage adjustment range50.0-72.0 V Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-28.8V 25.0-36.0V 30.0-43.2V 40.0-57.6V 50.0-72.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)94 % Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>3.7V*N Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >3.7V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Pre-charge current3.32±10% A Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 6.6A±10% 5.4A±10% 4.0A±10% 3.32A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity16 - 160 Ah Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 33 - 330Ah 27 - 270Ah 20 - 200Ah 16 - 160Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-720166; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 5 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-546220 | 90–264 VACConfiguration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Li-ionConfiguration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤2.2 ±20% AConfiguration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLi-ion Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Li-ion battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤2.2 ±20% A Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤2.8A ±20% ≤2.2A ±20% ≤2.0A ±20% ≤1.4A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part. Charging current22.0±10% A Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 28.0A±10% 22.0A±10% 20A±10% 14.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-546220; G1300 family feature statement, PDF page1; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage54.6±1% V Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 29.4V±1% 42.0V±1% 54.6V±1% 58.8V±1% 84.0V±1% Charging-voltage adjustment range32.5-54.6 V Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 17.5-29.4V 25.0-42.0V 32.5-54.6V 35-58.8V 50.0-84.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency94 % Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (full load @ AC230V.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY & EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)110% max. output Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer writes 110% max. output without explicitly stating voltage versus another output quantity; preserved literally. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage 110% max. output Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @Full load Pre-charge current4.4±10% A Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 5.6A±10% 4.4A±10% 4.0A±10% 2.8A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity22 - 220 Ah Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 28 - 280Ah 22 - 220Ah 20 - 200Ah 14 - 140Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-546220; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 3 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-432270 | 90–264 VACConfiguration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | LiFePO4Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | Not published | User-defined or factory-default CAN protocolConfiguration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤2.7 ±20% AConfiguration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLiFePO4 Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LiFePO4 battery chargers Battery leakage current (typical, source notation)≤1Ma Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source notation gap: the manufacturer prints ≤1Ma with ambiguous capitalization. The value is preserved literally; it is not silently normalized to mA or interpreted as megaamperes. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1Ma Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤2.7 ±20% A Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤3.3A ±20% ≤2.7A ±20% ≤2.0A ±20% ≤1.66A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current27±10% A Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 33.0A±10% 27A±10% 20.0A±10% 16.6A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-432270; G1300 family feature statement, PDF page1; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage43.2±1% V Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 28.8V±1% 36.0V±1% 43.2V±1% 57.6V±1% 72.0V±1% Charging-voltage adjustment range30.0-43.2 V Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-28.8V 25.0-36.0V 30.0-43.2V 40.0-57.6V 50.0-72.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)94 % Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>3.7V*N Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >3.7V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Pre-charge current5.4±10% A Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 6.6A±10% 5.4A±10% 4.0A±10% 3.32A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity27 - 270 Ah Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 33 - 330Ah 27 - 270Ah 20 - 200Ah 16 - 160Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-432270; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 3 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-840140 | 90–264 VACConfiguration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Li-ionConfiguration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤1.4 ±20% AConfiguration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLi-ion Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Li-ion battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤1.4 ±20% A Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤2.8A ±20% ≤2.2A ±20% ≤2.0A ±20% ≤1.4A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part. Charging current14.0±10% A Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 28.0A±10% 22.0A±10% 20A±10% 14.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-840140; G1300 family feature statement, PDF page1; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage84.0±1% V Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 29.4V±1% 42.0V±1% 54.6V±1% 58.8V±1% 84.0V±1% Charging-voltage adjustment range50.0-84.0 V Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 17.5-29.4V 25.0-42.0V 32.5-54.6V 35-58.8V 50.0-84.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency94 % Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (full load @ AC230V.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY & EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)110% max. output Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer writes 110% max. output without explicitly stating voltage versus another output quantity; preserved literally. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage 110% max. output Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @Full load Pre-charge current2.8±10% A Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 5.6A±10% 4.4A±10% 4.0A±10% 2.8A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity14 - 140 Ah Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 28 - 280Ah 22 - 220Ah 20 - 200Ah 14 - 140Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-840140; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 5 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-420280 | 90–264 VACConfiguration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | Li-ionConfiguration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | ≤1 mAConfiguration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. | User-defined or factory-default CAN protocolConfiguration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤2.8 ±20% AConfiguration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLi-ion Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Li-ion battery charger Battery leakage current (typical)≤1 mA Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery ≤1mA Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤2.8 ±20% A Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤2.8A ±20% ≤2.2A ±20% ≤2.0A ±20% ≤1.4A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part. Charging current28.0±10% A Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 28.0A±10% 22.0A±10% 20A±10% 14.0A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-420280; G1300 family feature statement, PDF page1; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage42.0±1% V Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 29.4V±1% 42.0V±1% 54.6V±1% 58.8V±1% 84.0V±1% Charging-voltage adjustment range25.0-42.0 V Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 17.5-29.4V 25.0-42.0V 32.5-54.6V 35-58.8V 50.0-84.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency94 % Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (full load @ AC230V.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY & EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curve for more details.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)110% max. output Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer writes 110% max. output without explicitly stating voltage versus another output quantity; preserved literally. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage 110% max. output Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @Full load Pre-charge current5.6±10% A Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 5.6A±10% 4.4A±10% 4.0A±10% 2.8A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity28 - 280 Ah Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 28 - 280Ah 22 - 220Ah 20 - 200Ah 14 - 140Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-420280; Li-ion charging configuration; G1300 EN V1.02, PDF page 2; Manufacturer exact model column 2 in the Li-ion table, PDF page 2, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-576200 | 90–264 VACConfiguration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | LiFePO4Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | Not published | User-defined or factory-default CAN protocolConfiguration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤2.0 ±20% AConfiguration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLiFePO4 Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LiFePO4 battery chargers Battery leakage current (typical, source notation)≤1Ma Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source notation gap: the manufacturer prints ≤1Ma with ambiguous capitalization. The value is preserved literally; it is not silently normalized to mA or interpreted as megaamperes. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1Ma Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤2.0 ±20% A Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤3.3A ±20% ≤2.7A ±20% ≤2.0A ±20% ≤1.66A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current20.0±10% A Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 33.0A±10% 27A±10% 20.0A±10% 16.6A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-576200; G1300 family feature statement, PDF page1; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage57.6±1% V Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 28.8V±1% 36.0V±1% 43.2V±1% 57.6V±1% 72.0V±1% Charging-voltage adjustment range40.0-57.6 V Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-28.8V 25.0-36.0V 30.0-43.2V 40.0-57.6V 50.0-72.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)94 % Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>3.7V*N Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >3.7V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Pre-charge current4.0±10% A Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 6.6A±10% 5.4A±10% 4.0A±10% 3.32A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity20 - 200 Ah Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 33 - 330Ah 27 - 270Ah 20 - 200Ah 16 - 160Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-576200; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 4 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|
| G1300-360330 | 90–264 VACConfiguration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. | LiFePO4Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. | Not published | User-defined or factory-default CAN protocolConfiguration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. | ≤3.3 ±20% AConfiguration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. | Full specificationsSource-backed claimsSpecifications & evidenceSource-backed claims. Configuration, workload and evidence type matter when comparing products. Ac input-voltage range90–264 VAC Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input voltage range Note.4 90 - 264VAC Battery chemistryLiFePO4 Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LiFePO4 battery chargers Battery leakage current (typical, source notation)≤1Ma Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source notation gap: the manufacturer prints ≤1Ma with ambiguous capitalization. The value is preserved literally; it is not silently normalized to mA or interpreted as megaamperes. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Leakage current from battery (Typ.) ≤1Ma Can protocol configurationUser-defined or factory-default CAN protocol Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN communication protocol is defined by user, or using factory default protocol. Charge-end current≤3.3 ±20% A Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge-end current ≤4A ±20% ≤3.3A ±20% ≤2.7A ±20% ≤2.0A ±20% ≤1.66A ±20% Charge-state indicationRed: charging; green: charged; flashing red: error; optional LCD panel Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part Charging current33.0±10% A Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge current @AC230V 40.0A±10% 33.0A±10% 27A±10% 20.0A±10% 16.6A±10% Charging-curve stages4 Manufacturer specification Configuration: G1300-360330; G1300 family feature statement, PDF page1; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Family feature claim for lithium batteries; detailed Li-ion curve appears on PDF page 6. No automatic chemistry recognition is claimed. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Built- in 4 stage charging curve(For Lithium batteries) and 4 stage
charging curve(For Lead-Acid batteries ) Charging voltage36.0±1% V Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OUTPUT Charge voltage 28.8V±1% 36.0V±1% 43.2V±1% 57.6V±1% 72.0V±1% Charging-voltage adjustment range25.0-36.0 V Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charge voltage range 20.0-28.8V 25.0-36.0V 30.0-43.2V 40.0-57.6V 50.0-72.0V Communication interfacesCAN or RS-485; CAN is default Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)CAN / 485 ; CAN is default Conducted-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Conducted EN55032 FCC PART15 Class B Cooling methodFan convection Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Cooling Fan convection Derating applicabilityDerate at100–120VAC input or ambient above40°C; consult curves Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Dimensions (l × w × h)280 × 145 × 48 mm Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Dimension 280*145*48mm (L*W*H) Efficiency (typical)94 % Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Efficiency (Typ.) 93% 94% 94% 94% 94% Harmonic-current standardEN61000-3-2 Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Harmonic Current EN61000-3-2 ..... Input current (typical)14 A Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Input current (Typ.) 14A@100VAC Input-to-output insulation test voltage3,000 V Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Hi-Pot Insulation i/p to o/p: 3000V (1 min) Inrush current (typical)75 A Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Inrush current (Typ.) Cold start 75A @230VAC Lcd accessory provisionOptional display/setting panel Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)LCD display/setting panel is an optional part when place order. Manufacturer-listed immunity standardsEN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11 Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 Manufacturer-listed safety standardIEC62368 Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Safety standards IEC62368 Manufacturer-stated mtbf30,000 h Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)OTHERS MTBF 30000H Maximum case temperature rise<40 °C Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)SAFETY& EMC (Note.6) Max. temperature rise < 40℃ on casing Maximum output power1200 W Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W Measurement reference conditions230VAC input; rated load;25°C ambient Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)1. Modification for charger specification may be required for different battery specification. Please contact battery
vendor or Green digital power for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient
temperature.
3. This is general suggested. Please consult your battery manufacturer about maximum charging current limitation.
4. Derating is needed at AC100~120V input or above 40℃ ambient. Please check the derating curves.
5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the
whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to
"EM I testing of component power supplies."
7. CAN communication protocol is defined by user, or using factory default protocol.
8. LCD display/setting panel is an optional part when place order. Operating ambient-temperature range-10 to +40 °C Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve") Operating humidity0–90 % RH Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Working humidity 0 - 90% RH Overtemperature protectionOutput shuts down and recovers automatically after temperature decreases Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over temperature Shut down output, recovers automatically after temperature goes down Overvoltage protection threshold (source notation)>3.7V*N Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Over voltage >3.7V*N Power factor (typical)>0.96 Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Power factor (Typ.) PF>0. 96 @full load Pre-charge current6.6±10% A Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Pre-charge current 8A±10% 6.6A±10% 5.4A±10% 4.0A±10% 3.32A±10% Programmable charging parametersCharging voltage, charging current and battery type via CAN Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or
our LCD display panel accessary to set these parameters. Radiated-emission standardEN55032; FCC Part15; ClassB Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Radiated EN55032 FCC PART15 Class B Rated ac input frequency50 / 60 Hz Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Rated ac input voltage100–240 VAC Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)INPUT Rated input voltage 100 - 240VAC 50 / 60Hz Recommended battery capacity33 - 330 Ah Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Recommended battery capacity Note.3 40 - 400Ah 33 - 330Ah 27 - 270Ah 20 - 200Ah 16 - 160Ah Reverse-polarity protectionInternal relay Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Reverse polarity By internal relay Short-circuit protectionOutput shuts down Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)PROTECTION Short circuit Note.5 Protection type : Shut down output Standby input power< 4 W Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Standby input power < 4W Storage humidity0–95 % RH Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Storage temperature-40 to +70 °C Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Storage temperature, humidity -40 - +70℃, 0 - 95% RH Vibration-resistance test claim10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes Voltage-flicker standardEN61000-3-3 Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Voltage Flicker EN61000-3-3 ..... Weight1,800 g Manufacturer specification Configuration: G1300-360330; LiFePO4 charging configuration; G1300 EN V1.02, PDF page 3; Manufacturer exact model column 2 in the LiFePO4 table, PDF page 3, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)Weight 1800g |
|---|