Product details

G1300-888130

Robot Batteries and Power Components

GREEN Digital Power

G1300-888130

About this product

G1300-888130 is a GREEN Digital Power G1300 programmable AC/DC desktop battery charger, explicitly listed in the manufacturer Lead-acid charging table. Its stated charging voltage is 88.8 V (±1%) and charging current is 13.0 A (±10%) at 230 VAC. The family is intended for EV, robot and AGV charging and supports configurable charging parameters through CAN, with RS-485 and an optional LCD panel described by the manufacturer. Input and temperature derating, battery compatibility and the chemistry-specific conditions in Specifications apply. Cover image: Manufacturer series image; size may vary. The manufacturer family reference illustration shows one labeled electrical configuration; printed output ratings and connector options are not exact-model proof for every listed variant. The datasheet gives inconsistent lead-acid stage counts; both source claims remain visible in Specifications.

Model
G1300-888130
Category
Robot Batteries and Power Components, Components

Specifications & evidence

Source-backed claims. Configuration, workload and evidence type matter when comparing products.

Ac input-voltage range

90–264 VAC

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input-range claim is distinct from full-power operation. Manufacturer Note 4 requires derating at AC100–120V; consult the actual curve.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Input voltage range Note.4 90 - 264VAC

Battery chemistry

Lead-acid

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The table explicitly assigns this model to this battery chemistry; programmable options do not create additional physical model identities.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Lead-Acid battery charger

Battery leakage current (typical)

≤1 mA

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Leakage current from battery (Typ.) ≤1mA

Can protocol configuration

User-defined or factory-default CAN protocol

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Protocol choice does not establish a separately orderable physical SKU.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
CAN communication protocol is defined by user, or using factory default protocol.

Charge-end current

≤2.6 ±20% A

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. The manufacturer prints an upper-limit inequality together with ±20% tolerance; both qualifiers are retained without inventing a stricter effective threshold.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Charge-end current ≤8.0A ±20% ≤5.4A ±20% ≤4.0A ±20% ≤3.2A ±20% ≤2.6A ±20%

Charge-state indication

Red: charging; green: charged; flashing red: error; optional LCD panel

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Bi-color LED is the source indicator; LCD display is optional, not supplied by default.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
CHARGE INDICATOR Red charging, Green charged, RED-FLASHING ERRORS; LCD digital panel is an optional part

Charging current

13.0±10% A

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Specified at AC230V. The ±10% tolerance is retained.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Charge current @AC230V 40.0A±10% 27.0A±10% 20.0A±10% 16.0A±10% 13.0A±10%

Charging-curve stages

4

Manufacturer specification

Configuration: G1300-888130; lead-acid family feature statement, PDF page1; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page1 feature text says4 stages for lead-acid, while page6 explicitly labels3 stages. Both claims are preserved; no arbitrary correction.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Built- in 4 stage charging curve(For Lithium batteries) and 4 stage charging curve(For Lead-Acid batteries )

Charging-curve stages

3

Manufacturer specification

Configuration: G1300-888130; lead-acid charging-curve heading, PDF page6; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer source conflict: page6 curve heading says3 stages for lead-acid while page1 feature text says4. Float-voltage row is retained separately; no source claim is silently selected.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
3 stage charging curve(Lead-Acid battery charger)

Charging-voltage adjustment range

60.0-88.8 V

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Charge voltage range 20.0-29.6V 30.0-44.4V 40.0-59.2V 50.0-74.0V 60.0-88.8V

Communication interfaces

CAN or RS-485; CAN is default

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source page1 explicitly identifies CAN or RS485. No separately named interface SKU or simultaneous-interface behavior is inferred.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
CAN / 485 ; CAN is default

Conducted-emission standard

EN55032; FCC Part15; ClassB

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Conducted EN55032 FCC PART15 Class B

Cooling method

Fan convection

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Cooling Fan convection

Derating applicability

Derate at100–120VAC input or ambient above40°C; consult curves

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note 4. Lead-acid note prints AV100~120V; this apparent AC/AV notation difference is recorded without changing the exact quote. No curve point is numerically interpolated.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power for details. 2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation. 4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves 5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on. 6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component power supplies." 7. CAN communication protocol is defined by user, or using factory default protocol. 8. LCD display/setting panel is an optional part when place order.

Dimensions (l × w × h)

280 × 145 × 48 mm

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Printed parameter-table dimensions. Drawing page7 labels47.7 for height; the table appears rounded. No separate hardware revision is inferred from that precision difference.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Dimension 280*145*48mm (L*W*H)

Efficiency (typical)

94 %

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Li-ion table explicitly states full load at AC230V. Other chemistry tables use the Note2 defaults:230VAC, rated load and25°C. The first column is93%; other columns are94%.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Efficiency (Typ.) 93% 94% 94% 94% 94%

Float charging voltage

82.8±1% V

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Float charge(Low voltage) 27.6V±1% 41.4V±1% 55.2V±1% 69.0V±1% 82.8V±1%

Harmonic-current standard

EN61000-3-2

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Harmonic Current EN61000-3-2 .....

High charging voltage

88.8±1% V

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
OUTPUT Charge voltage (High voltage) 29.6V±1% 44.4V±1% 59.2V±1% 74.0V±1% 88.8V±1%

Input current (typical)

14 A

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At100VAC input.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Input current (Typ.) 14A@100VAC

Input-to-output insulation test voltage

3,000 V

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Input to output,1minute. AC/DC waveform is not specified.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Hi-Pot Insulation i/p to o/p: 3000V (1 min)

Inrush current (typical)

75 A

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Cold start at 230 VAC.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Inrush current (Typ.) Cold start 75A @230VAC

Lcd accessory provision

Optional display/setting panel

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Must be specified when ordering; not claimed as included equipment.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
LCD display/setting panel is an optional part when place order.

Manufacturer-listed immunity standards

EN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-8; EN61000-4-11

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No test levels or pass criteria are supplied in this row. Whole-system compliance must be reconfirmed per Note6.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
EMC IMMUNITY EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11

Manufacturer-listed safety standard

IEC62368

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer-listed standard only; no independent certificate review or specific edition is asserted.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Safety standards IEC62368

Manufacturer-stated mtbf

30,000 h

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. No prediction method, confidence level or lifetime guarantee is supplied.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
OTHERS MTBF 30000H

Maximum case temperature rise

<40 °C

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Temperature rise on casing, not an absolute casing-temperature limit.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
SAFETY& EMC(Note.6) Max. temperature rise < 40℃ on casing

Maximum output power

1200 W

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Maximum at AC120–240V; low-line and ambient-temperature derating still apply. The family maximum is not an unconditional output at every voltage/current setting.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Max. output@AC120~240V 1200W 1200W 1200W 1200W 1200W

Measurement reference conditions

230VAC input; rated load;25°C ambient

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note2 explicitly supplies the defaults except where a row states otherwise.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor or Green digital power for details. 2.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 3.This is general suggested. Please consult your battery manufacturer about maximum charging current limitation. 4.Derating is needed at AV100~120V input or above 40℃ ambient. Please check the derating curves 5.This protection mechanism is specified for the case the short circuit occurs after the charger is turned on. 6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component power supplies." 7. CAN communication protocol is defined by user, or using factory default protocol. 8. LCD display/setting panel is an optional part when place order.

Operating ambient-temperature range

-10 to +40 °C

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Refer to manufacturer derating curve; Note 4 discusses derating above 40°C. That note does not establish unrestricted operation above the printed range.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve")

Operating humidity

0–90 % RH

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Working humidity 0 - 90% RH

Overtemperature protection

Output shuts down and recovers automatically after temperature decreases

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Over temperature Shut down output, recovers automatically after temperature goes down

Overvoltage protection threshold (source notation)

>15.5V*N

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Source formula is retained exactly. N is not defined in this table or its notes; no cell count, nominal voltage or absolute threshold is inferred.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Over voltage >15.5V*N

Power factor (typical)

>0.96

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. At full load. The source typesets 0. 96 with an internal space; numeric notation is normalized without changing the strict greater-than sign.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Power factor (Typ.) PF>0. 96 @full load

Programmable charging parameters

Charging voltage, charging current and battery type via CAN

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. A PC terminal or the optional LCD display panel can configure the parameters; source does not establish all settings over every interface.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Charging parameters (voltage, current, battery type) can be set via CAN port. User can use PC terminal or our LCD display panel accessary to set these parameters.

Radiated-emission standard

EN55032; FCC Part15; ClassB

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
EMC Emission Radiated EN55032 FCC PART15 Class B

Rated ac input frequency

50 / 60 Hz

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
INPUT Rated input voltage 100 - 240VAC 50 / 60Hz

Rated ac input voltage

100–240 VAC

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
INPUT Rated input voltage 100 - 240VAC 50 / 60Hz

Recommended battery capacity

50 - 130 Ah

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. General recommendation only. Note3 requires checking the battery manufacturer maximum charging-current limit; no universal pack compatibility is implied.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Recommended battery capacity 160 - 400Ah 100 - 300Ah 80 - 200Ah 60 - 160Ah 50 - 130Ah

Reverse-polarity protection

Internal relay

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Reverse polarity By internal relay

Short-circuit protection

Output shuts down

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Note5 applies specifically when the short circuit occurs after the charger is turned on; startup into a short is not established.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
PROTECTION Short circuit Note.5 Protection type : Shut down output

Standby input power

< 6 W

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Chemistry-table claim: lead-acid gives <6W; the lithium tables give <4W. Do not merge those different source configurations.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Standby input power < 6W

Storage humidity

0–95 % RH

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Storage temperature, humidity -40 - +70℃, 0 - 95% RH

Storage temperature

-40 to +70 °C

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Storage temperature, humidity -40 - +70℃, 0 - 95% RH

Vibration-resistance test claim

10–50Hz;2G;10min per cycle;60min on each X,Y,Z axis

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Frequency, acceleration notation, cycle duration and each-axis duration are preserved. Source does not define the waveform or acceptance criterion.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Vibration resistance 10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes

Voltage-flicker standard

EN61000-3-3

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results. Manufacturer EMC claim for the charger as an independent unit. Note6 requires the final equipment to reconfirm whole-system EMC compliance. Source prints dots instead of a test-level value; no level is inferred.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Voltage Flicker EN61000-3-3 .....

Weight

1,800 g

Manufacturer specification

Configuration: G1300-888130; Lead-acid charging configuration; G1300 EN V1.02, PDF page 4; Manufacturer exact model column 5 in the Lead-acid table, PDF page 4, linked filename EN V1.02. Measurement defaults in Note 2 are 230 VAC input, rated load and 25°C ambient unless otherwise stated. These are manufacturer claims, not independent test results.

GREEN G1300 programmable battery charger datasheet (linked filename EN V1.02)
Weight 1800g

Related products

Contact Us

If you have any questions or would like to get in touch, please feel free to reach out to us at the email below.

info@robotuo.com

YOUR CHOICES

Privacy settings

Choose each optional purpose. All are off until you agree. Change or withdraw consent at any time; browsing still works if you reject all.

Privacy preference

Remembers the choice you make here.

Always active

Save comparisons and followed companies and products between visits. Turning this off deletes saved selections; you can still use them during this visit.

Allow Google Analytics through Firebase to measure general page visits and usage with cookies and device information. Advertising remains off.

Allow OneSignal to process browser and subscription information for Robotuo news and updates. Browser permission is a separate step.

Your shortlist

0 companies selectedUp to 10

Your shortlist is empty. Browse companies and add the ones you’d like to connect with.