Product details

G600-441136

Robot Batteries and Power Components

GREEN Digital Power

G600-441136

About this product

G600-441136 is a GREEN G600 desktop charger for Lead-acid batteries, rated at 44.1±1% V and 13.6±10% A, with a rated-power cell of 599.76 with its unit omitted. USB configures charging parameters; CAN or RS485 connects external equipment, and an LCD displays charging information. Its fan-cooled 240 × 117 × 66 mm chassis weighs 1.5 kg. It accepts 90–264 VAC, with low-line and temperature derating; the stated operating ambient range is -10 to +40°C. Cover image: Manufacturer series image; size may vary. Manufacturer reference illustration. The manufacturer image shows a family configuration; the screen label and connector options do not establish every electrical setting.

Model
G600-441136
Category
Robot Batteries and Power Components, Components

Product family: G600 programmable battery chargers

Specifications & evidence

Source-backed claims. Configuration, workload and evidence type matter when comparing products.

Ac-input derating curve corner values

90% load at 90 VAC; 100% at 100 VAC and through the labeled 264 VAC range

Manufacturer specification

Configuration: G600-441136; manufacturer diagram, PDF page 5; Visual reading of explicitly labeled corners and plateau on PDF page 5; no interpolation. The input acceptance range remains 90–264 VAC, while full output is separately subject to output configuration and temperature limits.

GREEN G600 programmable charger family datasheet
LOAD (%) 100 90 80 70 60 90 100 120 150 220 240 264 AC input voltage (V)

Ac input-voltage range

90–264 VAC

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Input acceptance is distinct from full power. Note 4 and the actual curve require low-line derating.

GREEN G600 programmable charger family datasheet
Input voltage range Note.4 90 - 264VAC

Battery chemistry

Lead-acid

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Lead-Acid battery charger

Battery leakage current (typical)

≤1 mA

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Leakage current from battery (Typ.) ≤1mA

Can connector pin assignment

1 CANH; 2 5V+; 3 CANL; 4 5V−

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. PDF page 7 connector-view numbering. Signal/power notation is literal; no current capability or connector interoperability inferred.

GREEN G600 programmable charger family datasheet
Pin No. Assignment 1 CANH 2 5V+ 3 CANL 4 5V-

Charge-end current

≤2.7 ±20% A

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Upper inequality and printed ±20% tolerance are both retained; no invented effective cutoff threshold.

GREEN G600 programmable charger family datasheet
Charge-end current ≤7A ±20% ≤4A ±20% ≤2.7A ±20% ≤1A ±20% ≤1.6A ±20%

Charging current

13.6±10% A

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Charge current 34.0A±10% 20.0A±10% 13.6A±10% 10.2A±10% 8.1A±10%

Charging-curve stages

3

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. The chemistry headings and detailed curve panel agree on the stage count. No automatic chemistry detection is claimed.

GREEN G600 programmable charger family datasheet
Built- in 4 stage charging curve(For Lithium batteries) and 3 stage charging curve(For Lead-Acid batteries )

Charging stages

Constant current; high constant voltage; low constant voltage (float)

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Detailed lead-acid panel, PDF page 6; use the exact model high/float voltage rows rather than multiplying an undefined N.

GREEN G600 programmable charger family datasheet
Constant current Constant voltage(H) Constant voltage(L)

Charging-voltage adjustment range

25-44.1 V

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Charge voltage range 10-14.7V 17.5-29.4V 25-44.1V 35-58.8V 42.5-73.5V

Conducted-emission standard

EN55032; FCC Part15; Class B

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Charger-unit manufacturer claim. Note 6 requires final-system EMC confirmation; omitted test levels are not inferred.

GREEN G600 programmable charger family datasheet
Conducted EN55032 FCC PART15 Class B

Configuration interface

USB; battery chemistry, charging voltage and charging current

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Requires suitable configuration for the actual battery; options do not create separate model records.

GREEN G600 programmable charger family datasheet
The battery type (Lead acid, Lithium battery,LiFePO4 battery), charging voltage and charging current can be set by USB interface, Communication with external devices via CAN or RS485.

Cooling method

Fan convection

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Cooling Fan convection

Derating applicability

Low-input voltage derating; consult manufacturer curves

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. No interpolated curve value is presented. The operating-temperature range remains explicit.

GREEN G600 programmable charger family datasheet
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and Green digital power for details. 2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 3. This is Green suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on. 6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component power supplies."

Dimensions (l × w × h)

240 × 117 × 66 mm

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Dimension 240*117*66mm (L*W*H)

Efficiency (typical)

92 %

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Efficiency (Typ.) 90% 92% 92% 93% 93%

External communication

CAN or RS485

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. The source states alternatives; simultaneous availability, supplied protocol and separate interface SKUs are not established.

GREEN G600 programmable charger family datasheet
The battery type (Lead acid, Lithium battery,LiFePO4 battery), charging voltage and charging current can be set by USB interface, Communication with external devices via CAN or RS485.

Float charging voltage

41.4±1% V

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Float charge(Low voltage) 13.8V±1% 27.6V±1% 41.4V±1% 55.2V±1% 69V±1%

Harmonic-current standard

EN61000-3-2

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Charger-unit manufacturer claim. Note 6 requires final-system EMC confirmation; omitted test levels are not inferred.

GREEN G600 programmable charger family datasheet
Harmonic Current EN61000-3-2 .....

High charging voltage

44.1±1% V

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
OUTPUT Charge voltage (High voltage) 14.7V±1% 29.4V±1% 44.1V±1% 58.8V±1% 73.5V±1%

Input current (typical)

6.8 A

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. At 100 VAC.

GREEN G600 programmable charger family datasheet
Input current (Typ.) 6.8A@100VAC

Input-to-output insulation test voltage

3,000 V

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. One-minute test; AC/DC waveform not stated.

GREEN G600 programmable charger family datasheet
Hi-Pot Insulation i/p to o/p: 3000V (1 min)

Inrush current (typical)

75 A

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Cold start at 230 VAC.

GREEN G600 programmable charger family datasheet
Inrush current (Typ.) Cold start75A @230VAC

Lcd current-display error

±6 %

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
CHARGE INDICATOR LCD display Display voltage(Display error ± 2%), current(Display error ± 6%), capacity

Lcd diagram readouts

Battery type; voltage; current; state of charge; charging time; charging energy; charging capacity

Manufacturer specification

Configuration: G600-441136; manufacturer diagram, PDF page 6; Manufacturer LCD diagram on PDF page 6. Illustrated screen values are examples and are not assigned as this model charging settings. Readout resolution, time/energy/capacity accuracy and capacity-estimation method are unspecified.

GREEN G600 programmable charger family datasheet
Battery type Voltage Current State of Charge Charging Time Charging energy Charging capacity

Lcd readouts

Charging voltage, current and capacity

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
CHARGE INDICATOR LCD display Display voltage(Display error ± 2%), current(Display error ± 6%), capacity

Lcd voltage-display error

±2 %

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
CHARGE INDICATOR LCD display Display voltage(Display error ± 2%), current(Display error ± 6%), capacity

Manufacturer-listed immunity standards

EN61000-4-2; -3; -4; -5; -6; -8; -11

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. No test levels or pass criteria stated. Final-system EMC still requires confirmation.

GREEN G600 programmable charger family datasheet
EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4- EMC IMMUNITY 11

Manufacturer-listed safety standard

IEC62368-1

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Manufacturer claim; no certificate or standard edition independently verified.

GREEN G600 programmable charger family datasheet
Safety standards IEC62368-1

Manufacturer-stated mtbf

30,000 h

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Prediction method, confidence and test conditions unspecified; not a lifetime guarantee.

GREEN G600 programmable charger family datasheet
OTHERS MTBF 30000H

Maximum case temperature rise

<40 °C

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Temperature rise on the casing, not an absolute casing limit.

GREEN G600 programmable charger family datasheet
SAFETY&EMC (Note.6) Max. temperature rise < 40℃ on casing

Measurement reference conditions

230 VAC input; rated load; 25°C ambient

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Overrides apply where an individual row states a different condition.

GREEN G600 programmable charger family datasheet
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and Green digital power for details. 2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 3. This is Green suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on. 6. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EM I testing of component power supplies."

Operating ambient-temperature range

-10 to +40 °C

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Refer to derating graph. The graph extends to 60°C; this does not erase the printed -10 to +40°C operating range.

GREEN G600 programmable charger family datasheet
ENVIRONMENT Working temperature -10 - +40℃ (Refer to " Derating Curve")

Operating humidity

0–90 % RH

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Working humidity 0 - 90% RH

Overtemperature protection

Output shutdown; automatic recovery after cooling

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Over temperature Shut down output, recovers automatically after temperature goes down

Overvoltage protection threshold (source notation)

>15.5V*N

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. The source uses N without defining it in this table/notes. No cell count or absolute cutoff is inferred.

GREEN G600 programmable charger family datasheet
Over voltage >15.5V*N

Power factor (typical)

>0.98

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. At 100 VAC and full load. Internal source spacing in 0. 98 is normalized.

GREEN G600 programmable charger family datasheet
Power factor (Typ.) PF>0. 98@AC100V,Full load

Radiated-emission standard

EN55032; FCC Part15; Class B

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Charger-unit manufacturer claim. Note 6 requires final-system EMC confirmation; omitted test levels are not inferred.

GREEN G600 programmable charger family datasheet
EMC Emission Radiated EN55032 FCC PART15 Class B

Rated ac input frequency

50 / 60 Hz

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
INPUT Rated input voltage 100 - 240VAC 50 / 60Hz

Rated ac input voltage

100–240 VAC

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
INPUT Rated input voltage 100 - 240VAC 50 / 60Hz

Rated output power

599.76

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. At Note 2 reference conditions; low-input and ambient-temperature derating apply. This is not unconditional full power at every voltage/current setting. Unit omission: this exact cell prints bare 599.76 while adjacent cells include W; preserve the literal value with unit unspecified rather than silently supplying W.

GREEN G600 programmable charger family datasheet
Rated power 499.8W 588W 599.76 599.76W 595.35W

Recommended battery capacity

30 - 100 Ah

Manufacturer specification

Configuration: G600-441136; Lead-acid table; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. General recommendation only; Note 3 requires the battery vendor maximum charging-current limit to be respected.

GREEN G600 programmable charger family datasheet
Recommended battery capacity 60 - 200Ah 40 - 150Ah 30 - 100Ah 20 - 80Ah 15 - 60Ah

Reverse-polarity protection

Internal relay

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Reverse polarity By internal relay

Rs485 connector pin assignment

1 RS485-B; 2 5V+; 3 RS485-A; 4 5V−

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. PDF page 7 connector-view numbering. Signal/power notation is literal; no current capability or connector interoperability inferred.

GREEN G600 programmable charger family datasheet
Pin No. Assignment 1 RS485-B 2 5V+ 3 RS485-A 4 5V-

Short-circuit protection

Output shutdown

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Note 5 specifies a short occurring after the charger has been turned on; startup into a short is not established.

GREEN G600 programmable charger family datasheet
PROTECTION Short circuit Note.5 Protection type : Shut down output

Standby input power

<2.5 W

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Standby input power < 2.5W

Storage humidity

0–95 % RH

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Storage temperature, humidity -40 - +70℃, 0- 95% RH

Storage temperature

-40 to +70 °C

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Storage temperature, humidity -40 - +70℃, 0- 95% RH

Thermal derating curve corner values

100% load from -10 to 40°C; line ends at 60% load at 60°C before a vertical drop

Manufacturer specification

Configuration: G600-441136; manufacturer diagram, PDF page 5; Visual reading of explicitly labeled line segments and corners on PDF page 5; no intermediate point is digitized or interpolated. This graph is a source-qualified diagram claim. The rated operating-temperature table still says -10 to +40°C; the graph does not establish unrestricted rated operation at 60°C. The vertical endpoint is not interpreted as a guaranteed control/shutdown threshold.

GREEN G600 programmable charger family datasheet
LOAD (%) 100 80 60 40 20 -10 10 20 30 40 50 60 AMBIENTTEMPERATURE(℃)

Usb charge-end-current configuration

Programmable through USB

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Family description on PDF page 1, not a separate hardware variant.

GREEN G600 programmable charger family datasheet
G600 can be set different charging voltage value, charging current value and charging end current value through USB,

Vibration-resistance test claim

10–50 Hz; 2 G; 10 min/cycle; 60 min on each X/Y/Z axis

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Source does not define waveform or acceptance criterion.

GREEN G600 programmable charger family datasheet
Vibration resistance 10-50Hz,2G10min.1cycle,60min.eachalongX,Y,Zaxes

Voltage-flicker standard

EN61000-3-3

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested. Charger-unit manufacturer claim. Note 6 requires final-system EMC confirmation; omitted test levels are not inferred.

GREEN G600 programmable charger family datasheet
Voltage Flicker EN61000-3-3 .....

Weight

1,500 g

Manufacturer specification

Configuration: G600-441136; common hardware; G600 family PDF page 4; Exact manufacturer model column in the Lead-acid table, PDF page 4. Note 2 defaults: 230 VAC input, rated load and 25°C ambient unless a row states otherwise. Manufacturer claims; not independently tested.

GREEN G600 programmable charger family datasheet
Weight 1500g

Related products

Contact Us

If you have any questions or would like to get in touch, please feel free to reach out to us at the email below.

info@robotuo.com

YOUR CHOICES

Privacy settings

Choose each optional purpose. All are off until you agree. Change or withdraw consent at any time; browsing still works if you reject all.

Privacy preference

Remembers the choice you make here.

Always active

Save comparisons and followed companies and products between visits. Turning this off deletes saved selections; you can still use them during this visit.

Allow Google Analytics through Firebase to measure general page visits and usage with cookies and device information. Advertising remains off.

Allow OneSignal to process browser and subscription information for Robotuo news and updates. Browser permission is a separate step.

Your shortlist

0 companies selectedUp to 10

Your shortlist is empty. Browse companies and add the ones you’d like to connect with.